Ürün Ayrıntıları
Hava hacmi:
1500m³/saat-40000m³/saat
İşlev:
Verimli ve enerji tasarrufu sağlayan, ısıtma, nemlendirme, nem alma ve dezenfeksiyon
Panel Malzemesi:
Çift katmanlı izolasyon paneli, renkli çelik sac, galvanizli çelik sac, paslanmaz çelik sac
İsim:
Isı Geri Kazanımlı Klima Santrali
Ürün özellikleri:
Verimli ve enerji tasarrufu sağlayan
Ürün adı:
Özelleştirilmiş Temiz Hava işleyicisi, ameliyathane için hava işleme ünitesi
Vurgulamak:

Heat Recovery Unit factory price

,

Fresh Air Handling Unit equipment

,

Heat Recovery Ventilation system

Ödeme ve Nakliye Şartları
Min sipariş miktarı
Bir
Fiyat
Pazarlıklı
Ambalaj bilgileri
Özel ambalaj filmi
Teslim süresi
35 iş günü
Ödeme koşulları
Banka havalesi, T/T
Yetenek temini
Ayda 100 Birim
Ürün Tanımı
Heat Recovery Fresh Air Handling Unit Equipment Factory Price
ISO-certified Heat Recovery Air Handling Unit manufacturer from China, featuring environmental friendliness and energy-saving design. An air handling unit (AHU) with heat recovery is a core HVAC (Heating, Ventilation, and Air Conditioning) device that integrates heat recovery functionality into a standard air handling unit.
Key Working Principles
A heat-recovery unit re-uses the air from the building to warm or cool new fresh air. A typical unit features two fans, one to reuse the building air (Return Fan), and the other to bring in fresh air (Supply Fan). What makes a heat recovery unit unique is the heat-exchange core.
The core transfers heat from the outgoing stream to the incoming stream in the same way that the radiator in your car transfers heat from the engine's coolant to the outside air. It's composed of a series of narrow alternating passages through which incoming and outgoing air streams flow. As the streams of air move through, heat is transferred from the warm side of each passage to the cold, while the airstreams never mix. Westaire can implement different types of heat-exchangers which best accommodate your air temperature requirements.
Heat Recovery Fresh Air Handling Unit Equipment  Factory Price  0 Heat Recovery Fresh Air Handling Unit Equipment  Factory Price  1
JETEX Heat Recovery Air Handling Unit
Our company has developed an innovative heat recovery air handling unit that uses water as the thermal transfer medium. By employing specialized wet-film fillers, the unit facilitates cross-counterflow heat and moisture exchange between spray water and indoor exhaust air in an open-system total heat recovery process.
During operation, the indoor exhaust air and outdoor fresh air remain entirely separated, completely eliminating air cross-contamination to ensure clean and healthy air quality. After open-system recovery, the air enters a sealed system, maintaining zero contact between exhaust and fresh air--100% cross-contamination prevention for guaranteed air purity.
Key Features
  • High Efficiency & Energy Savings
  • Easy installation, can choose a multi-functional packed unit with exhaust air, heat recovery, fresh air functions or a single-function machine, to meet the usage needs of different environments such as new construction projects and renovation projects.
  • Enhanced Heat Exchange Performance - By reducing airflow duration and volume through the heat exchanger, dust accumulation on its surface is minimized, indirectly improving thermal exchange efficiency.
Air Handling Unit with Heat Recovery (HRAHU)
Item Key Details
Core Function Heat/cold transfer between exhaust air and fresh air; energy-saving ventilation
Heat Exchanger Type Common: Plate heat exchanger, rotary heat exchanger (enthalpy wheel), run-around coil
Heat Recovery Efficiency 60%-90% (varies by exchanger type; plate type: 60%-75%, rotary type: 75%-90%)
Air Volume Range 500-100,000 m³/h (suitable for small offices to large industrial plants)
Operating Temperature -20°C to 45°C (outdoor air temperature; low-temperature models available for cold regions)
Air Quality Guarantee Independent air streams (no cross-contamination); optional filters (G3-H14 grade)
Control Features Automatic temperature sensing, heat recovery switch, airflow regulation
Key Materials Cabinet: Galvanized steel (anti-corrosion); Heat exchanger: Aluminum alloy/Stainless steel
Typical Energy Saving 15%-40% reduction in HVAC operating energy consumption
Heat Recovery Fresh Air Handling Unit Equipment  Factory Price  2
Our Certificates
Heat Recovery Fresh Air Handling Unit Equipment  Factory Price  3
Our Exhibitions
Heat Recovery Fresh Air Handling Unit Equipment  Factory Price  4
For information about Heat Recovery Fresh Air Handling Unit, please contact US and get talented air solutions!

Sorunuzu doğrudan bize gönderin

Gizlilik Politikası Çin İyi Kalite Hava işleme üniteleri Tedarikçi. Telif hakkı © 2024-2025 GUANGZHOU JETEX-LLOYD'S MACHINERY LTD - Tüm haklar saklıdır.